HINA R&P  TECHNOLOGY  AND EQUIPMENT


























                    Figure 6  Distribution and application of electric heating technology in curing press components

               The steam thermal valve groups designed, developed, and   hand-pull valves, etc., as shown in figure 7.
           manufactured by MESNAC can be broadly divided into two
           forms in terms of structural style. One form is the single valve
           connected through welded flange pipelines to achieve control of
           the curing medium. That is, the valve + flange + pipeline form,
           simply referred to as the traditional valve group mode. In the
           traditional mode, the thermal valve group of the curing press
           is divided into four parts: the external temperature inlet valve
           group, the external temperature return valve group, the internal
           temperature inlet valve group, and the internal temperature
           return valve group. The other form is the integrated thermal
           valve group, which designs the valve's switching function for
           the medium inside the valve block. The valve block serves
           both as a process flow channel and as a valve body. The valve
           is an external pneumatic actuator that controls the valve's   Figure 7 Steam-heated thermal pipeline
           switching. Overall, the integrated thermal valve group of the
           curing press integrates the four separately designed pipelines   4.2  Structure of electric heating component
                                                                 The electric heating system designed, developed, and
           of the external temperature inlet valve group, external
                                                             manufactured by MESNAC eliminates the boiler, auxiliary
           temperature return valve group, internal temperature inlet
                                                             equipment, and thermal valve group system as shown in figure
           valve group, and internal temperature return valve group into
                                                             8. The direct effect is the reduction of at least 6 circuits of 18
           one valve group according to actual conditions, or integrates
                                                             various valves, simplifying the pipeline arrangement at the
           the internal temperature inlet and return valve groups into one
                                                             rear of the equipment. The nitrogen circulation heating system
           valve group, and integrates the external temperature inlet and
                                                             for electric heating mainly includes: regulating valve, pressure
           return valve groups into one valve group. This form of pipeline
                                                             sensor, Roots blower, pressure sensor, nitrogen heating device,
           integration and valve group integration is simply referred to as
                                                             temperature sensor, etc.
           the integrated thermal valve group mode. Steam-type thermal
           valve groups generally include shut-off valves, check valves,
           filters, pneumatic diaphragm regulating valves, self-operated   5  Comparison of social benefits between
           pressure regulating valves, solenoid valves, mechanical valves,   electric heating and steam heating.